125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Solis DLS-W WiFi Data Logger Installation Guide : Solis Press the button for 5 seconds to reset2 red lights are on and off at the same time. You will have full control of your system whenever and wherever you are. AGL replaced the data logger a few months back and it has worked perfectly since then. Standard Warranty Document : Solis Copyright@2020 Ginlong Technologies All rights reserved, Data Logger is fairly similar to the Cellular Data Logger's process. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . If its not pingable, the password is good, the signal strength is good then login to the router and check the customers firewall protections. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stick, Solis DLS-G GPRS Datalogger setup and troubleshooting, Adding a new inverter to an existing EPM set-up, EPM 5G Plus- Abnormal Offline on Soliscloud. Have contacted the company who sold me it. If the WIFI stick doesn't show a connected inverter check the address of the inverter. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Communication quality may be affected in lightning storms. An example of data being processed may be a unique identifier stored in a cookie. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed cultures. Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection.Solis monitoring system can be monitored remotely by WIFI to provide users accurate and comprehensive data analysis and fault alarm at any time and place,, make product operation . No, Modified on: Tue, Oct 4, 2022 at 2:54 PM. Note that all scripts use Python 3. I will ask AGL for a replacement. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stickadmin page. You will need to have theSolisCloudapp downloaded on your phone. Sorry we couldn't be helpful. Solis datalogger installation instructions APP Enso Circle Space 2.1K subscribers Subscribe 84K views 3 years ago This instructional video shows you how to setup the WIFI monitoring on your. GitHub - simon3270/ginlong-python: Get logging data from Solis Inverter Solis Data Logging Stick GPRS/WiFi Installation Video Solis 46.7K subscribers 15K views 9 months ago Solis monitoring system is centred around the photovoltaic power station, focusing on. Shows the power supply status of the datalogger. Help us improve this article with your feedback. signal at the inverter for there to be a stable connection. Copyright@2020 Ginlong Technologies All rights reserved, If the network is not appearing, press and hold the Reset button down for 10 seconds until both NET and COM lights start to flash simultaneously, This network must be 2.4GHz as 5GHz networks are not supported. 5. I haven't been able to log onto it after many attempts. Model: AP300 Hardware Version: V11. You can rerun the wizard and see if that works. Every solar system, regardless of size and complexity benefits from monitoring and this datalogger is the gateway to the informative online platform, SolisCloud. Shows the connection status between the datalogger and the inverter. This device complies with part 15 of the FCC Rules. No-Grid - El inversor no reconoce la red. Note: the SolisWiFilogger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. Press and hold power button to turn on your hotspot. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed; Reset WiFi Stick to Factory Settings solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right All is fine for about a week and then I noticed that the system would go offline a couple of times throughout the day (morning and night) with varying durations. 2. PDF WiFi Instructions - Solis inverters are designed to last longer! This process can also be used to move a Solis Data Logger from one site to another. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . first report in, so please wait until the system begins to show data on. SolisCloud - New generation Solis PV monitoring platformuk - Ginlong Manage Settings I'm having the same issue, just tried setting it up but says it's offline, light on the stick is red, anything I should be checking? Required fields are marked *. Step 5: Long press the Reset button for 5 seconds until the yellow and green LEDs are quickly flashing. Open navigation. Internal DC Short: In the inverter head, or the wirebox? solis SOL-DLS-W Data Logger Wifi Stick User Guide - Manuals+ Solis WiFi Data Logger Installation Guide, Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the displayed list of plants, Tap on the plant, then tap "Device" towards the top just to the right of "Overview", Tap "Datalogger" and then left-swipe the logger with your finger - you will see "Delete" in red to the right of the device, Tap "Delete" and then tap "Delete" again when asked if you want to disassociate the datalogger, "Deleted successfully" should appear - swipe down on the page to refresh it - the deleted datalogger should disappear from the device list as shown below, The deleted datalogger can now be installed on a different site/inverter, if that was the intention, A new datalogger can be installed at this site/on this inverter now that the old one has been removed. After you connect verify the WIFI stick sees the inverter. My data logger turned out to be faulty. Verify the RSSI (signal strength) is higher than 15%. Thanks Peter. 3: Set a manual IP for the computer using the following information -, (The IP of the computer must be with 10.10.100.XXX range to configure the LAN stick). If you have aSolisCloudaccount already, then please follow the steps below to create a plant and commission a SolisWiFidata logger to the system. WiFi datalogger firmware is out of date. Why is my solis inverter offline? Explained by Sharing Culture Router signal strength is low 4. Monitoring Accessory Configured But Still Won't Link? Michael is the author of this solution article. If you run through the setup wizard and are still having problems I suggest you contact them. If the connection is weak (1-2 bars) then it is recommended to install a. range extender to boost the signal strength where the logger is going to be. The scripts will process data from the WiFi and LAN Data . Go to your web browser - Input 10.10.100.254 4. We pay our respects to their Elders past, present and emerging. Sorry we couldn't be helpful. PDF c Ginlong Tech Ginlong Tech Preferred I'm Plant Owner Build Your Plant :). *, We appreciate your effort and will try to fix the article. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Plug the logger into the inverter - be sure the inverter is on with at least DC power, Open the Wi-Fi settings on your phone and then search for new networks, Look for a network called "Solis_XXXXXXXXXX" the "XXXXXXXX" should be the serial number of the logger, Open a browser on your phone and enter 10.10.100.254 into the address bar, Enter "admin" for the password and "123456789" for the password then hit Log In, Go to Quick Set and then tap Search in the top left corner, Select the local Wi-Fi network that you wish to use, Enter the Wi-Fi network password (be sure that it is correct) and then tap Save, If everything was done correctly, the "Solis_XXXXX" network should disappear and the NET/COM lights on the logger should begin flashing, At this point you can go to SolisCloud and add the data logger to your plant, Use the scanner to scan the QR code sticker on the logger, Place your hand behind the logger if the scanner is not working (this helps it to focus), If you are still not having luck scanning the logger you can enter the serial number manually, Go to the Device tab on your plant and then to the Data Logger tab, The data logger should now be displayed here with note about when it last reported. You will benefit from upgraded accurate fault alarm messaging that is adjustable to notify you within hours that fit meet your needs. Dataloggers can be scanned or added manually by entering in the serial number. My data logger appears to be working fine but I also notice it now glows red, appears to be a red LED inside the logger. Verify the address is set to "1". Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. 2: On the computer, click on the Network Connections and select the Local Connection. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Step 6: Wait for around 10 seconds. If you hate cookies, or are just on a diet, you can disable them altogether too. In order to to set an IP address you can use a Mobile Phone, Tablet or Computer. Solar Inverters | String Inverters | Energy storage inverters - Ginlong Technician check pins 1 and 2 for 5VDC, 3. The [RESET] button on the back is used for the connection. AGL replaced it free of charge. Select Network, fill in the IP address assigned by the router/network administrator. When I am logged into the data logger via wifi the status says that it is connected and when I test the connection on the server page it seems to be all good. A Solis 5K inverter is used here as an example. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //.